  • Stilla Technologies – Digital PCR – Naica 6 colors system

    The Naica® System

    Get absolute quantification of multiple genetic targets in a single run

    Digital PCR (dPCR) is a powerful tool ...

    The Naica® System

    Get absolute quantification of multiple genetic targets in a single run

    Digital PCR (dPCR) is a powerful tool used for the precise and highly sensitive quantification of nucleic acids.

    The naica® system is an easy-to-use dPCR platform that harnesses cutting-edge microfluidic technology to integrate the dPCR workflow onto a single consumable chip. The technology, known as Crystal Digital PCR™, partitions samples into a large array of thousands of individual droplet crystals – each its own reaction compartment – before amplifying nucleic acid molecules in each droplet crystal. These reactions are tagged with fluorophores to be read using up to six different fluorescence light channels.

    This makes for a fast and simple workflow that provides even more sensitivity while reducing time to results and saving precious sample.

  • Surface Measurement Systems – DVS Adventure

    The DVS Adventure is an advanced water vapor sorption analyzer that enables unparalleled accuracy and detailed insight into the sorption properties of solid-state materials.

    Employing the Dynamic Vapor ...

    The DVS Adventure is an advanced water vapor sorption analyzer that enables unparalleled accuracy and detailed insight into the sorption properties of solid-state materials.

    Employing the Dynamic Vapor Sorption Method, the DVS Adventure contains the cumulative knowledge of 25 years’ worth of Surface Measurement Systems’ excellence in vapor generation, measuring sorption and desorption isotherms over a broad range of humidities and temperatures.

  • Surface Measurement Systems – DVS Carbon

    The latest addition to the DVS family, DVS Carbon, is the first purpose-built gravimetric sorption analyzer for advanced carbon capture, utilization, and storage (CCUS) applications. In most gas phase carbon capture applications...

    The latest addition to the DVS family, DVS Carbon, is the first purpose-built gravimetric sorption analyzer for advanced carbon capture, utilization, and storage (CCUS) applications. In most gas phase carbon capture applications, CO2 often competes with other chemical species at adsorbent sites, including water vapor. The new DVS Carbon enables the measurement of CO2 uptake in real life conditions, controlling both temperature and humidity at a broad range of CO2 concentrations.

    With the patented Surface Measurement Systems Ultrabalance measuring real-time mass changes caused by sorption and desorption in the sample, complex carbon capture conditions can be assessed in a range of materials. In addition, the system can be configured to enable a range of different capabilities.

  • Surface Measurement Systems – DVS Endeavour

    Offering the highest throughput of our entire DVS range, the DVS Endeavour precisely controls and measures temperature and relative humidity while simultaneously recording the highest resolution changes in mass on up to 5 sample...

    Offering the highest throughput of our entire DVS range, the DVS Endeavour precisely controls and measures temperature and relative humidity while simultaneously recording the highest resolution changes in mass on up to 5 samples simultaneously.

    Combined with a range of modular accessories, the DVS Endeavour is one of the most versatile DVS instruments on the market.

  • Surface Measurement Systems – DVS Resolution

    The world’s most advanced DVS Instrument, the DVS Resolution is a dual vapor gravimetric analyzer that brings unparalleled capabilities and precisions to the study of complex sorption behaviors.

    The i...

    The world’s most advanced DVS Instrument, the DVS Resolution is a dual vapor gravimetric analyzer that brings unparalleled capabilities and precisions to the study of complex sorption behaviors.

    The instrument has the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass.

  • Surface Measurement Systems – Dynamic Vapor Sorption Instruments

    Dynamic vapor sorption is a valued tool in laboratories all over the world, within R & D, from polymorphism and compound stabilit...

    Dynamic vapor sorption is a valued tool in laboratories all over the world, within R & D, from polymorphism and compound stability studies to bulk and surface adsorption effects of water and organic vapours. It is a vital part of quality control analysis techniques for both scale-up and production, and can even be found within the packaging arena, measuring both the efficacy and permeability of packaging, and the effects of humidity and temperature on the samples within the packaging.

     

  • Surface Measurement Systems – Inverse Gas Chromatography – Surface Energy Analyzer (iGC-SEA)

    The iGC-SEA continues Surface Measurement Systems’ pioneering history with inverse gas chromatography (iGC), which now spans more than fifteen years.

    The iGC-SEA is a second generation iGC instrument....

    The iGC-SEA continues Surface Measurement Systems’ pioneering history with inverse gas chromatography (iGC), which now spans more than fifteen years.

    The iGC-SEA is a second generation iGC instrument. It is the world’s only commercial instrument based on the iGC principle. The unique SMS injection scheme provides a wide range of injection concentrations with unrivalled accuracy and reproducibility.

    How Does the iGC-SEA Work?

    The iGC-SEA is based on Inverse Gas Chromatography (iGC) methodology and is a gas phase technique for characterising surface and bulk properties of solid materials. The principles of IGC are very simple, being the reverse of a conventional gas chromatographic (GC) experiment.A cylindrical column is uniformly packed with the solid material of interest, typically a powder, fibre or film. A pulse of constant concentration of gas is then injected down the column at a fixed carrier gas flow rate, and the time taken for the pulse or concentration front to elute down the column is measured by a detector. A series of iGC measurements with different gas phase probe molecules then allows access to a wide range of phyisco-chemical properties of the solid sample.

    The injected gas molecules passing over the material adsorb on the surface with a partition coefficient KS:

    Ks = Vn / Ws

    Where VN is the net retention volume – the volume of carrier gas required to elute the injection through the column, and WS is the mass of the sample. VN is a measure of how strongly the probe gas interacts with the solid sample and is the fundamental data obtained from an IGC experiment; from it a wide range of surface and bulk properties can be calculated.

  • Systech Illinois – O2 analyzer – OxySense 325i

    This base oxygen analyzer is used in conjunction with a computer interface and will perform most of the functions of the 5250i including non-invasive headspace analysis for packages, bottles and blister packs using the O2xyDot Sensor; package mate...

    This base oxygen analyzer is used in conjunction with a computer interface and will perform most of the functions of the 5250i including non-invasive headspace analysis for packages, bottles and blister packs using the O2xyDot Sensor; package material and design evaluation; closure design and evaluation; MAP production start up monitoring; research and development; QC and assurance, as well as product oxidation studies.

    The OxySense 325i is particularly ideal for smaller laboratories and companies considering bringing their oxygen testing requirements in-house for the first time and companies looking for a low-cost solution. With the new EasAlign Pen with integrated capture switch for a simple, one click, oxygen measurement. Multiple measurements can be provided over time on the same package offering accurate analysis through real time, real world measurements. Due to the measurement process used, the risk of sample contamination or leaks is eliminated.

  • Systech Illinois – O2 analyzer – OxySense 5250i

    The OxySense 5250i is the o2 analyzers instrument of choice for laboratories and individuals who need to test or evaluate packaging materials through a variety of studies. These studies include: non-invasive headspace analysis for packages, bottle...

    The OxySense 5250i is the o2 analyzers instrument of choice for laboratories and individuals who need to test or evaluate packaging materials through a variety of studies. These studies include: non-invasive headspace analysis for packages, bottles and blister packs using the O2xyDot Sensor; package material and design evaluation; closure design and evaluation; MAP production start up monitoring; research and development; QC and assurance, as well as product oxidation studies.

    For non-invasive measurements, oxygen concentration can be determined by placing the O2xyDot Sensor in the package or container prior to filling and sealing. Multiple measurements can be provided over time on the same package offering accurate analysis through real time, real world measurements. Due to the measurement process used, the risk of sample contamination or leaks is eliminated.

    This versatile instrument also has the capability to perform permeability analysis (OTR) on film, bottles and packages*.

  • Systech Illinois – O2 CO2 Tester, the headspace gas analyzer – Gaspace Advance

    This carbon dioxide (CO2) and oxygen (O2) headspace analyzer provides consistently reliable results and simplicity in operation allowing you to maximise your production efficiency. Its large buttons and clear display ensures te...

    This carbon dioxide (CO2) and oxygen (O2) headspace analyzer provides consistently reliable results and simplicity in operation allowing you to maximise your production efficiency. Its large buttons and clear display ensures testing is simple, errors are eliminated and no special operator training is required.

    Numerous packs can be tested quickly with just one button press, saving time and making Quality Assurance more efficient. These MAP analyzers can test all pack sizes and very low volumes.

    Rigid cans and jars can also be tested using the simple-to-use can piercing station which supports the cans and jars for accurate analysis using a standard needle probe. A 45° Adaptor is also available to aid measurement of small volumes of headspace.

    There are a variety of ways to perform analysis; Timed Tests, AutoSense, Peak/Valley, Syringe Direct Injection or Continuous Testing. Fast configuration and selection provides the test method which is best for you. Easy to see Pass and Fail messages speeds up the analysis process and removes any uncertainty with interpreting measurements.

    The Gaspace Data Manager software allows you to download results stored on your gas analyzer and upload new settings. You can also search through your stored data by time, date, user, production line or any of the product information.

  • Systech Illinois – Package Testers – TME BT Integra-Pack™

    The TME BT Integra-Pack© is a bench-top, highresolution (0.001 psig) test instrument with a small footprint and user-friendly ease of operation. Electronic pressure and flow controls provide precise and repeatable test conditio...

    The TME BT Integra-Pack© is a bench-top, highresolution (0.001 psig) test instrument with a small footprint and user-friendly ease of operation. Electronic pressure and flow controls provide precise and repeatable test conditions, while automatic and high flow output allow testing of large porous packages. Applications cover a range of flexible or rigid, porous and non-porous, open or sealed packages.

    Automatic or Manual Parameter Definition 

    The intelligent BT Integra-Pack will test any package in automatic mode, with no need to input test parameters. However, its sophisticated nature is combined with a manual mode that lets the user input parameters such as ramp rate control and back pressure drop sensitivity. This allows testing of special configurations or types of packages or perform specific research and datagathering activities.

    Icon-based, Touch-Driven Color Display

    The touchscreen color display provides easy, clear navigation through the wide variety of data handling and review screens. Clearly defined icons make it easy to choose test modes, move from automatic to manual test settings, view test results in numeric and/or graphical format, and securely handle accumulated data.

  • Systech Illinois – Water Vapor Permeation Analyzer – 7000

    Modular systems for precision water vapor permeabilty testing of packaging film barriers.

    The 7000 water vapor analyzer range utilises the sensitive and stable P2O5 sensor for absolute moisture measurem...

    Modular systems for precision water vapor permeabilty testing of packaging film barriers.

    The 7000 water vapor analyzer range utilises the sensitive and stable P2O5 sensor for absolute moisture measurement. These water vapor analyzers offer a wide measurement range of 0.002-1000 g/m²/day and precision temperature, humidity and flow control. Providing accurate and repeatable results for research and development testing of water transmission rate (wvtr) in both current and newly formulated packaging film materials and fast testing for Quality Control.

    All Systech Illinois analyzers are certified traceable to NIST. In addition, analytical performance is validated using NIST certified gases and NIST traceable films.

    A set of validation films and a spare P2O5 sensor comes as standard with all of our water vapor permeation analyzers.

  • TME – Package Testers – the smart BT Integra-Pack

    This completely integrated process control tool offers accurate package test results which can be transmitted directly to your quality control department. Its objective is to validate a package ensuring that it matches the high standard of the product enclosed.

    The BT Integra-Pack© is a high-resolution (0.001 psig), bench-top test instrument with a small footprint and user-friendly ease of operation. Electronic pressure and flow controls provide precise and repeatable test conditions while automatic and high flow output allow testing of large porous packages. Applications cover a range of flexible or rigid, porous and non-porous, open or sealed packages.

    This intelligent instrument can test any package in automatic mode without the need to input test parameters. However, its sophisticated nature is combined with a manual mode that lets the user input parameters such as ramp rate control and back pressure drop sensitivity. This allows testing of special configurations or types of packages or perform specific research and data-gathering activities.

  • TMI – Coefficient of Friction/Peel tester – Model 32-76e

    Testing Machines Inc., is globally recognized as the leading supplier of coefficient of friction instrumentation. Our NEW 32-76e coefficient of friction/peel tester uses advanced digital force signaling and high-speed data acquisition software to ...

    Testing Machines Inc., is globally recognized as the leading supplier of coefficient of friction instrumentation. Our NEW 32-76e coefficient of friction/peel tester uses advanced digital force signaling and high-speed data acquisition software to provide unmatched precision and repeatability in COF and peel testing.

    Improved features include a color touchscreen display and intuitive software user interface for easy navigation and test method storage.

    New peel testing capabilities include 180° peel and T-peel measurements.

  • TMI – Compression Tester

    Microprocessor control and operator-friendly software makes the 17-76 simple to operate. A new Servo motor design provides closed loop feedback for accurate and repeatable position control.  Ergonomic control layout maximizes t...

    Microprocessor control and operator-friendly software makes the 17-76 simple to operate. A new Servo motor design provides closed loop feedback for accurate and repeatable position control.  Ergonomic control layout maximizes the testing sequence while minimizing sample testing errors resulting in incorrect data.  The instrument meets or exceeds all international testing standards for accuracy, precision, and parallelism.

    System software includes 8 corrugated test methods for quick access including: RCT, CCT, ECT, CMT, FCT, PAT, CLT and SQT- score test which calculates score ratio of scored verses unscored samples.  Test methods can be created by the operator and stored for future reference to simplify test set up. Other compression methods include peak force, peak height and stack load.